{"product_id":"thermalec-electric-heater","title":"Thermalec Titanium Electric Heater","description":"\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cp\u003eNow with titanium elements.\u003c\/p\u003e\n\u003cp\u003eCast iron heater body.\u003c\/p\u003e\n\u003cp\u003eHeavy fusion bonded epoxy coating.\u003c\/p\u003e\n\u003cp\u003eImpervious to salt and chemically treated pool water.\u003c\/p\u003e\n\u003cp\u003e35psi design pressure operating at a normal working pressure of 30psi gives protection to the whole installation.\u003c\/p\u003e\n\u003cp\u003eDrain valve allows the heater to be emptied for winterisation.\u003c\/p\u003e\n\u003cp\u003eRemovable upVC stub flanges mean no unions or heat sink are required.\u003c\/p\u003e\n\u003cp\u003eFlow direction is left ot right, can be reversed on site.\u003c\/p\u003e\n\u003cp\u003eCopper, incoloy or titanium elements individually mounted in a removable top plate.\u003c\/p\u003e\n\u003cp\u003eAllows easy element renewal and inspection of the interior of the vessel.\u003c\/p\u003e\n\u003cp\u003e2A fuse protects the control circuit.\u003c\/p\u003e\n\u003cp\u003eMinimum of 6 indicator lamps monitor every stage of operation for simple diagnostic servicing.\u003c\/p\u003e\n\u003cp\u003eSingle Phase: 3kW-6kW\u003c\/p\u003e\n\u003cp\u003eSingle \u0026amp; Three Phase: 7.5kW-24kW\u003c\/p\u003e\n\u003cp\u003eThree Phase: 30kW-72kW\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCast in BS-EN-1561-1997-ENGJL-200 iron, with a heavy fusion bonded epoxy coating impervious to chemically treated pool water, constructed in accordance with British Patent 2.092,282 Design pressure of 35psi (2.46kg\/cm2) with 3\/4\" safety valve(s) set to operate at the maximum normal working pressure of 30psi (2.1kg\/cm2) giving protection to both the heater and and the installation as a whole against over pressure. A 1\/2\" drain valve at the lowest point allows the heater to be left empty in winter. Flow connections consist of easily removable uPVC stub flanges into which the pipes may be fitted using suitable adhesive, as the flanges can be released easily from the heater no unions are required, nor is any form of heat sink needed. Flow direction is from left to right, but may be reversed quite simply on site following the installation instructions. \u003c\/p\u003e\n\u003cdiv class=\"webeditCoreRow\" id=\"webedit.content.9.colourblock\" style=\"padding: 0 0 14px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"wRow wColourblock wBackground7 webeditLightText\" style=\"padding: 24px; width: 692px;\"\u003e\n\u003cdiv class=\"webeditCoreColumn\" style=\"margin: 0px 0px -14px; min-height: 15px;\"\u003e\n\u003cdiv class=\"webeditCoreRow webeditOptionsComponent\" id=\"webedit.content.9.colourblock.colourblock.column0\"\u003e\n\u003cdiv class=\"webeditCoreRow\" id=\"webedit.content.9.colourblock.colourblock.column0.3.showhide\"\u003e\n\u003cdiv class=\"webeditCoreRow webeditShowhideComponent\" id=\"webedit.content.9.colourblock.colourblock.column0.3.showhide.showhide\"\u003e\n\u003cdiv class=\"webeditCoreRow webeditShowhideTrigger\" style=\"padding-bottom: 14px;\" onclick=\"W.toggleDisplay(document.getElementById('webedit.content.9.colourblock.colourblock.column0.3.showhide.showhide.content'));\"\u003e\n\u003cdiv class=\"wRow webeditTextComponent\"\u003e\n\u003cdiv class=\"webeditText\"\u003e\n\u003cdiv\u003e\u003cspan class=\"bon twss\"\u003eFEATURES \u0026gt; \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"webedit.content.9.colourblock.colourblock.column0.3.showhide.showhide.content\" class=\"webeditCoreRow\" style=\"display: block;\"\u003e\n\u003cdiv class=\"webeditCoreRow webeditOptionsComponent\" id=\"webedit.content.9.colourblock.colourblock.column0.3.showhide.showhide.options\"\u003e\n\u003cdiv class=\"webeditCoreRow\" id=\"webedit.content.9.colourblock.colourblock.column0.3.showhide.showhide.options.1.text\" style=\"padding: 0 0 14px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"wRow webeditTextComponent\"\u003e\n\u003cdiv class=\"webeditText\"\u003e\n\u003cdiv class=\"dl\"\u003eThe construction of the heater is solid and robust, to ensure years of safe and reliable service. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe contact materials are highly resistant to corrosion from pool chemicals. Thermalec® pool and spa heaters can safely be used with sea water pools as well as in demanding applications such as Hydro- and Thalasso- therapy. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe watts density of the heating elements is very low (9.54 W\/cm²), ensuring minimal scale build-up and long element life. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe heating elements are always submerged in water. Any air bubbles entering the heater pass through it above the water and across the unheated parts of the elements, preventing any damage to the latter. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe patented weir and baffle system inside the heater causes the water to flow through it in a spiral. This increases uniformity of the water temperature inside the heater and prevents direct impingement of cold water onto the elements. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe spiral flow regime of the water inside the heater discourages scale formation, extending element life. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe heaters have no flow switch. These are notoriously unreliable. Any air bubbles passing through the heater will cause any flow switch to make and break repeatedly in rapid succession, causing the contactors to do the same, thus shortening their life. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThermalec® heaters are flexible: The water flow direction is normally left to right. If required, this can be easily changed on installation by means of a simple modification. Most models may be easily changed by a qualified electrician from single to three phase operation and vice-versa. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eThe thermostats used in Thermalec® pool and spa heaters have a low operating differential. This is essential to maintain the swimming pool at a virtually constant temperature. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eHeaters with higher operating differentials are likely to allow the pool to cool to an uncomfortably low temperature before switching the heating on. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eTop quality contactors have been used and their ratings generously selected to give a long service life and minimum risk of operational problems, particularly in pool plant room \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003econditions. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eAs a safety precaution, the heaters are provided with an interlock relay, which has to be connected to the filter pump control circuit. The heater will not operate unless the interlock is wired and the filter pump is energised. \u003c\/div\u003e\n\u003cdiv class=\"dl\"\u003eStatus indicator lamps on front of panel to facilitate troubleshooting and diagnostics.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Thermalec","offers":[{"title":"6kW","offer_id":21902783175,"sku":"HT060T","price":1878.72,"currency_code":"GBP","in_stock":true},{"title":"7.5kW","offer_id":21902783239,"sku":"HT075T","price":2075.14,"currency_code":"GBP","in_stock":true},{"title":"9kW","offer_id":21902783303,"sku":"HT090T","price":2237.76,"currency_code":"GBP","in_stock":true},{"title":"12kW","offer_id":21902783431,"sku":"HT120T","price":2285.28,"currency_code":"GBP","in_stock":true},{"title":"15kW","offer_id":21902783559,"sku":"HT150T","price":3119.52,"currency_code":"GBP","in_stock":true},{"title":"18kW","offer_id":21902783687,"sku":"HT180T","price":3288.48,"currency_code":"GBP","in_stock":true},{"title":"21kW","offer_id":21902783879,"sku":"HT210T","price":3431.04,"currency_code":"GBP","in_stock":true},{"title":"24kW","offer_id":21902784071,"sku":"HT240T","price":3695.04,"currency_code":"GBP","in_stock":true},{"title":"30kW","offer_id":21902784199,"sku":"HT300T","price":4450.08,"currency_code":"GBP","in_stock":true},{"title":"36kW","offer_id":21902784263,"sku":"HT360T","price":4875.65,"currency_code":"GBP","in_stock":true},{"title":"48kW","offer_id":28265896583,"sku":"HT480T","price":5997.12,"currency_code":"GBP","in_stock":true},{"title":"60kW","offer_id":28265927111,"sku":"HT600T","price":6467.04,"currency_code":"GBP","in_stock":true},{"title":"72kW","offer_id":28265959047,"sku":"HT720T","price":7276.46,"currency_code":"GBP","in_stock":true},{"title":"96kW","offer_id":39739127922754,"sku":"HT960T","price":10569.6,"currency_code":"GBP","in_stock":true},{"title":"9kW for Spas","offer_id":28266119559,"sku":"HT090SPA-T","price":2781.6,"currency_code":"GBP","in_stock":true},{"title":"12kW for Spas","offer_id":28266166215,"sku":"HT120SPA-T","price":2786.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1177\/3662\/products\/1790441060.jpg?v=1471955189","url":"https:\/\/shop.pooltechservices.co.uk\/products\/thermalec-electric-heater","provider":"Pool Tech Services","version":"1.0","type":"link"}